CAD.5:5.4 - What an internal-path ablation does and does not establish

For the scalar noiseless plant x_{k+1}=a x_k+u_k, with a one-tick delayed observation y_k=x_{k-1}, the predictor

\hat x_k=a y_k+u_{k-1},\qquad u_k=-a\hat x_k

uses the executed-input history. Removing that input term while retaining the remaining gains gives u_k=-a^2x_{k-1}. At a=1.2, the resulting characteristic polynomial is \lambda^2-1.2\lambda+1.44; its roots have modulus 1.2, so this ablation is unstable.

It does not prove that every controller lacking that input-history path is unstable. Retuning the memoryless delayed-output law to u_k=-0.6x_{k-1} gives roots of \lambda^2-1.2\lambda+0.6, both with modulus \sqrt{0.6}<1. The latter establishes stabilization of this noiseless model, not the original predictor’s performance or a bounded-disturbance constraint guarantee.

Use the first comparison to explain why the tested realization depends on its internal path. Use an impossibility argument such as :5.2–:5.3 when claiming that the available information cannot meet a requirement under any controller in the stated class.