CAD.5:5.5 - Recover two coupled coordinates from observations at different times
The general construction in :4.5 is not a coordinate-by-coordinate delay correction. Consider
A=\begin{bmatrix}6/5&1/5\cr 1/10&4/5\end{bmatrix},\qquad B=I,
with disturbance radii (.04,.02) and measurement-error radius .005. At time k=2, use a first-coordinate observation sampled at time 0 and a second-coordinate observation sampled at time 1. Both samples and the applied u_0,u_1 are available before this estimate is used. After subtracting the known input response,
r=\begin{bmatrix}y_{1,0}\cr y_{2,1}-[0\ \ 1]u_0\end{bmatrix}, \quad O=\begin{bmatrix}1&0\cr 1/10&4/5\end{bmatrix}, \quad J=O^{-1}=\begin{bmatrix}1&0\cr -1/8&5/4\end{bmatrix}.
Thus \hat x_2=A^2Jr+A u_0+u_1. The second measurement contains w_{02}, the second coordinate of the first disturbance, so it is related to the uncertainty in the subsequent propagation. Writing w_0=(w_{01},w_{02}), w_1=(w_{11},w_{12}), and the two measurement errors as v_1,v_2, substitution gives
\eta_1=\frac65w_{01}-\frac3{10}w_{02}+w_{11} -\frac{141}{100}v_1-\frac12v_2,
\eta_2=\frac1{10}w_{01}-\frac1{40}w_{02}+w_{12} -\frac{47}{400}v_1-\frac{33}{40}v_2.
The exact coordinate radii for the stated box of original uncertainties are (.10355,.0292125). Using the separate Minkowski enclosure in :4.5 gives the larger radii (.11155,.0612125): the same w_{02} was allowed to vary separately in two occurrences. Both enclosures are valid; retaining the shared variable can save a margin that a conservative test would spend.
This calculation supplies a finite-window error set, not a controller or an all-time guarantee for this new plant. The next use is :4.6 with the required actions and continuation, or :4.7 when a planning-and-feedback interface is already selected. Repeated use also needs the other allowed sample windows and startup to be covered.