SYSE.Application:6.5 - 4. Place the decisive dimensional control and expose what it still lacks

The assembly receives a coated bore, so the supplied requirement applies to its finished diameter. Here the process supplies no qualified bound linking the pre-coating result to that diameter. The engineer therefore places the dimensional check after coating and before assembly. A pre-coating measurement remains useful for correcting machining. In a different process, a qualified bound on the change can already establish the final tolerance, as in SYSE.28:5. A separately ordered finished-part measurement still has to be performed or the order changed.

In this case no qualified finished-part measurement chain, applicable uncertainty result or receiving decision rule has been supplied. The path can identify where to place the control, which parts to measure, what measurement result is needed and which dependent action must wait.

For example, a returned number of 20.010 mm without the applicable procedure, uncertainty and subject identity is not yet the required conformance decision. Use the qualified measurement and acceptance Methods for the actual operation to select any required tolerance guard band and sampling plan.

For the measurement construction, PHY.9 helps construct the measuring interaction; C.16.MR/IR relate its recorded result to values compatible with the stated error constraints. The instrument, material, procedure and applicable error account must still be supplied for this bore. For statistical inference under a probability model of the records, use MMP.13, retaining the meaning of its uncertainty statement.

In a separate calculation the finished bore reads 20.014 mm. Suppose any additive reading error from −0.008 to +0.008 mm is possible, with no further restriction. Diameters 20.014 and 20.022 mm can each produce this reading. One meets the specification [19.980, 20.020] mm and the other exceeds it, so the reading leaves conformity undecided. An outer error bound alone would not establish that both diameters are possible. With a justified hard bound of ±0.004 mm for this same reading, every compatible diameter lies in [20.010, 20.018] mm and meets the dimensional specification. A statistical confidence interval calls for its own decision rule. Use C.11.DUA to weigh another measurement against improving the existing calculation when either could change the decision.

This calculation concerns the stated part and error model. Acceptance of a lot also needs its applicable decision and sampling rules.

Hold the acceptance decision for the identified finished lot until the necessary measurement and decision basis are available. Independent work on the interface, provider commitments or test preparation can continue.