Jump to text
On this page
Copy and source
Published source confirmed at last check

Source changed 2026-11-26 21:07:53 UTC · snapshot created 2026-11-26 21:08:36 UTC · last check 2026-11-29 22:35:20 UTC

SIE.5:5 - Archetypal Grounding - Semiconductor Recall Trace

A recall-triage query crosses a wafer identifier from a fabrication source, die coordinates, device serials, package identifiers, supplier lot identifiers, GS1 event identifiers, and an enterprise material master. The receiving question is whether a shipped device can be traced to an affected fabrication lot.

Endpoint questionConstructed disposition
wafer W-204 and supplier lot L-88not identity; the supplier record asserts that the wafer is a member/output associated with the lot under a bounded process interval. Preserve both identifiers and relation provenance.
die coordinate (x17,y9) on wafer W-204 and device serial D-771Suppose the packaging record shows that this die was incorporated in the serialized device. Trace the die as a constituent of that device for the recorded interval. A serial assigned to the singulated die itself can instead identify the same die as the wafer coordinate when the designation rule or identifiable context establishes that referent. In either case retain both source identifiers, their applicable intervals and the assignment, issuer or context that establishes each designation.
device serial D-771 and package code P-55unresolved because the package identifier is reused after rework and the event history lacks effectivity. Keep the exact package history open. Test whether this uncertainty changes the lot-level answer.
enterprise material master M-12 and device serial D-771The master record describes a product class and carries the enterprise attributes it governs. To classify the particular device, establish that it meets the class criterion. Membership in a catalogue family would require the catalogue’s own grouping rule. The master and the device each retain their identity.
GS1 event E-901 and device D-771event and object are different entities; the event may concern the device. Never merge their identifiers.

Tests cover reused package identifiers, a die split/merge error, contradictory supplier events, a missing cross-enterprise link, and a later correction. If the records admit at least one package history and every such history traces the shipped device to the affected lot, the interface can return that lot finding while keeping the P-55 history unresolved. If every admissible history excludes the affected lot, return that negative finding. If some lead to the affected lot and others exclude it, obtain the distinguishing rework or effectivity evidence or report the attribution still open. MDM or the domain steward may later decide a master identity; SIE.5 has not done so.