Jump to text
On this page
Copy and source
Published source confirmed at last check

Source changed 2026-11-26 21:07:53 UTC · snapshot created 2026-11-26 21:08:36 UTC · last check 2026-11-29 22:55:15 UTC

RHY.10:5.1 - A placement difference and accumulating drift

A constructed reference has event times 0.00, 0.50, 1.00 and 1.50 seconds. In the first response the events occur at 0.08, 0.58, 1.08 and 1.58 seconds. Each occurs 0.08 seconds after the corresponding reference event, and the intervals match. In the second the times are 0.00, 0.52, 1.04 and 1.56 seconds. The events are 0.52 seconds apart and their displacement from the reference grows by 0.02 seconds per interval.

Suppose the controller should coincide with the reference, the events have been identified correctly and the controller can re-enter at the future 2.00-second landmark. For this correction, the controller sets the output interval directly and the reference continues at its stated pace. In the first response, keep the 0.50-second interval and correct entry placement. In the second, shorten the interval to 0.50 seconds and re-establish entry at 2.00 seconds.

The times identify the change needed at the output. If the measurements come from a receiver, a growing delivery delay can yield the same series while the controller already runs at the required pace. Use §5.4 to locate the correction when that difference matters. Explaining a human performance requires evidence about that performer and passage. If the intended phrasing included an offset of 0.08 seconds, the first response would already meet the intended relation.