PHY.9:5.3 - Prepare a probe whose phase difference can be read

An ideal two-level probe couples to a constant classical field B through

H=(hbar gamma B/2) sigma_z,

where gamma is a known coupling coefficient and sigma_z has eigenvalues +1 and -1 for states |0> and |1>. Treat the field as unchanged by this probe during the interrogation time t. The wanted quantity is B within a supplied range.

Prepare |0>. Evolution multiplies it by a global phase; measurements of this state cannot reveal that phase. Increasing t alone does not create a readable field dependence.

Instead prepare |+>=(|0>+|1>)/sqrt(2). Evolution produces a relative phase phi=gamma B t. Reading sigma_z still gives equal probabilities and is uninformative about phi. A controlled rotation before detection permits a sigma_x or sigma_y measurement. The model predicts means cos(phi) and sin(phi). Together their exact values determine phase modulo 2 pi. Repeated preparations give a finite series of outcomes for each readout from which those means can be estimated.

For gamma=1 rad/(s·field-unit), t=1 s and B=pi/3 field-units, the ideal means are 1/2 and sqrt(3)/2. They select phi=pi/3 modulo 2 pi. On the supplied range -pi < gamma B t <= pi those ideal responses identify a unique field. A finite run can give the same outcome sequence at nearby field values in that range. For a conclusion about the measured field, infer the supported precision or uncertainty from the outcomes and their sampling law.

If the field may instead lie between -4 pi and 4 pi field-units, several fields give exactly the same pair of ideal means, however often the readout is repeated at this time. Shorten the initial interrogation, for example to t=0.1 s with the same gamma: the whole supplied range then lies inside the unambiguous phase interval. A later longer interrogation can refine a value once the remaining range supports its interpretation.

Coherence loss, imperfect rotations or an uncertain gamma change the response law. They can be included or constrained where the required estimate needs them.