Jump to text
On this page
Copy and source
Published source confirmed at last check

Source changed 2026-11-26 21:07:53 UTC · snapshot created 2026-11-26 21:08:36 UTC · last check 2026-11-29 22:40:20 UTC

OPS.18:4.2 - Select the evidence branch

Current questionEvidence methodFirst operating use
Has a recurring process changed from its established behavior?A suitable statistical monitor with a qualified baseline, sampling rule and response policy.Continue observation or investigate and contain the affected process/result.
Is event-based service meeting its objective?Definitions of good and eligible events, observation coverage, reporting window and permitted loss.Report the result against the objective. When a response is needed, apply the authorized policy or identify the missing decision.
Should a particular lot or result be accepted?The applicable acceptance terms and evidence for that lot or result. For sampling, include the qualified plan, defect definitions and risks.Accept, reject, segregate, rework or obtain the missing acceptance result.
Can an impaired service be restored or restarted?Evidence of the failure, containment or repair, and the required restart conditions.Restore service when its conditions hold under the appropriate authority. Continue an investigation if the remaining question requires it.
What prevention does an incident or near miss need?Reconstructed events, material explanations and sufficient support for feasible protective measures.Select and verify prevention under :4.4, retaining the limits on the causal conclusion.

Use the branches whose results affect the response or the grounds for relying on it. A monitoring signal, lot acceptance and authorization to restart each need evidence for that particular conclusion.

For recurring variation, check that the observations are comparable, the baseline is appropriate and the model fits the data. Changing sample size, seasonality, clustering, rare events or dependence can change the required monitor. When a simple chart is inadequate, use an applicable qualified design, develop one within your competence or obtain specialist help. Establish the defect or result definition, sampling, grouping, time order, baseline, plausible dependence or drift, costs of false and missed signals, and the latest useful response. A usable design identifies its population and model, detection and false-signal performance at specified changes, observation burden, and the rule the operator can execute.

For an event-based service, define the good and eligible events at the service boundary that matters to the recipient. Check omitted events, important subgroups and observation delay. A fast failure can require a timely alert before an end-of-window aggregate is available.

For acceptance, identify the item or result, the governing criterion and the evidence or act it calls for. A qualified statement tied to one item can suffice under its terms. For a lot accepted by sampling, recover the lot boundary, defect definitions, sampling rule and consequences of erroneous acceptance or rejection. Use the qualified plan already available or obtain the relevant expert contribution.