Jump to text
On this page
Copy and source
Published source confirmed at last check

Source changed 2026-11-26 21:07:53 UTC · snapshot created 2026-11-26 21:08:36 UTC · last check 2026-11-29 22:20:05 UTC

MNT.12:4 - Solution

Start from the receiving maintenance decision and its required distinctions. A spare-applicability question needs different history from a recurrence study or a hand-back. Select the unit, constituent histories or population and the times that could change that answer. Where several installation histories remain possible, use what all of them establish. Recover exact identities or dates when a difference changes the result or the order expressly requires them.

Recover the configuration basis under SYSE.13. Distinguish actual, intended and unknown installed state; part or variant descriptions; document editions; and the conditions under which a description applies. A date or shared label cannot establish those correspondences by itself.

Connect the maintenance events to that basis over time. Preserve relevant installation, removal, inspection, condition, intervention and restoration facts, including the sources that support them. Where exposure matters, establish which unit or component accumulated it during which interval and under what operating conditions. A replaced component does not inherit the predecessor’s age merely because the equipment tag is unchanged.

Resolve contradictions according to their consequence. A stock return may refer to unused material while the intervention record identifies the installed part. Resolve each identifier under the assignment or local rule in force at the time of the event. Compare what the two records say about the identified items and events before treating the records as inconsistent. If they conflict, use the available observation or accountable source that can resolve the receiving question; preserve uncertainty when it cannot.

Maintain the intended user’s ability to retrieve and interpret the result. Use the existing work log, engineering system or maintenance database when it can carry the necessary relations. Avoid copying one mutable current-state claim across several manually edited files. A source history can remain historical while one current account describes the relevant installed state.

Keep corrections distinguishable from new physical events. Correcting a mistaken serial number changes the account; replacing the component changes the machine. A Method or software change can also alter the meaning of a code without changing earlier events. Preserve the interpretation needed for comparison instead of silently recoding the past as if the categories were always identical.

Return the qualified information basis, its source links and any uncertainty that changes the next use. If the present question is answered, stop. Broader data repair is selected only when another use warrants the work. Follow the retention and access requirements that apply.

MNT.12:4.1 - First use with a replacement history

Use this practice when you can read maintenance records but still need to distinguish an entry date, an actual replacement and the interval belonging to each component. Make and retain your own answer before reading the discussion. The constructed time window uses equal operating conditions and continuous operation, so exposure here equals each component’s installed duration.

Make a first attempt. In [6,12), configuration C41 contains bearing R551 until its replacement at 8; C42 contains R607 from 8 onward. The replacement account was entered at 10. There is a condition observation at 7 and a functioning test at 9. The test records PS17 without an independent identification of the bearing’s serial number: its component attribution relies on the supported installation history. Allocate the exposure in this window and identify which configuration the observation and test concern. State the grounds for each attribution.

Choose an available edition containing Use a record for one configuration-dependent claim (SYSE.13:4.4), including its uncertain-time explanation, and keep that copy available for the exercise. Read that bounded fragment with your attempted answer in view. Return here with the actual component intervals, the relevant event times and any unresolved attribution. You need another part of SYSE.13 only if another configuration question requires it.

Compare your reasoning. R551 accumulates 8−6=2 time units and R607 accumulates 12−8=4, totaling 6. The observation at 7 concerns C41; the test at 9 concerns C42. Entry at 10 does not move the replacement from 8 to 10. Preserve R551’s earlier history; R607 does not inherit its predecessor’s exposure.

Revise the part of your answer whose grounds differ. Try each changed premise below before reading its discussion.

Corrected event account. Reconciliation of the original evidence establishes that replacement occurred at 10. The former boundary at 8 was an error in the account; its supported correction was entered at 11. What changes?

Discussion. R551 now has 4 time units and R607 has 2, still totaling 6. The test at 9 preceded replacement and no longer supports the former claim about testing C42/R607. This conclusion follows from the reconciled event evidence, not from preferring the latest entry. Correcting the account creates no second replacement. MNT.10 and MNT.11 retain the requirements for functioning evidence and resumed use; changing a record does not meet them.

Uncertain event time. For a separate variation, replace the exact replacement time with evidence of one transition τ∈[8,10] in the same [6,12) operating window. There were no other replacements or gaps. What exposure and test attribution can you still return?

Discussion. R551 has τ−6 time units and R607 has 12−τ. Each lies between 2 and 4, but they vary together: τ=8 → (2,4), τ=9 → (3,3), τ=10 → (4,2). The total remains 6 for every admissible time. It is not a range from 4 to 8. The observation at 7 still concerns the earlier configuration. The test at 9, without independent component identification, cannot be attributed confidently to R607.

Return the result at the scope the receiving question needs. A total-exposure question may use 6; a component-specific duration or restored-function question may require the actual boundary or separate evidence about the new component. Seek that relevant observation or accountable source answer when worthwhile; otherwise retain the uncertainty. Preserve unaffected history.

When practising transfer to another history, use one of your own event records and state which premise could change the answer. Use the explanations to correct your reading. The exercise supplies the time window, configuration history and attribution question. A correct solution shows how you used those premises. To assess your own choice of boundaries or evidence, use work in which you made that choice before receiving the answer. An earlier comparable record can suffice when it shows what you decided and what help you had. If that evidence is missing, try a suitable record with the assistance allowed for the task, leaving the choice under assessment to you. To credit the practice with a gain, compare what you could do before and can do now under relevant conditions. Establish what the practice contributed and obtain competent feedback where its contribution remains uncertain.