Jump to text
On this page
Copy and source
Published source confirmed at last check

Source changed 2026-11-26 21:07:53 UTC · snapshot created 2026-11-26 21:08:36 UTC · last check 2026-11-29 22:45:17 UTC

G.1:5 - Archetypal Grounding — Tell–Show–Show (informative)

Tell. Start with the work the kit must support on its next use. Which conditions will the new user supply, and which selection rules can the kit carry across commissions? The six cards make that design reusable and let a reader reconstruct the sources, candidates and decision for a completed use. The manifest identifies the cards of the kit edition.

Show A (R&D decisions about digitizing originals). A consortium wants a kit for deciding which imaging procedures a collection may use. In the first job the sheets are robust, and both a feeder and contactless photography satisfy all the job’s requirements, including page count and deadline. A second job differs only in the fragility of the originals. Under the applicable handling rule the feeder is forbidden on fragile sheets, while contactless photography remains admissible. The first job admits both procedures and the second only the contactless one. The author can now see which input the kit must obtain from the custodian and how it affects selection.

  • M1: state the decision, the physical collection under consideration, the deadline and the local information the selection requires, including the relevant handling condition. Pin the comparison specifications and reference plane.
  • M2: maintain the qualified handling rule and the sources that support each procedure’s claimed capabilities. Record the edition and applicability of each source in the SoTA set under G.2.
  • M3: retain the procedures in the candidate pool with their provenance. A procedure disallowed on one job can remain a candidate on another. Record generator policy for generated candidates and inclusion grounds for imported ones. If QD is used, follow G.1:Ext.NQD for descriptor and distance editions.
  • M4: combine the job’s handling condition with the acceptance predicates from G.4 and the selection specified in G.5. A fragile collection excludes feeding under this rule. If its condition is unknown and could change eligibility, identify that missing input. The outcome for this job belongs with its decision.
  • M5: index the reusable CHR/CAL/LOG and UTS contributions and the tests that depend on them.
  • M6: identify which selections to revisit if the handling rule changes or a procedure gains a qualified new capability. Use the refresh triggers from G.11.

Show B (clinical operations; safety‑first acceptability).

  • M1: scope a CG‑Frame around dose adjustment decisions; pin legality and evidence minima explicitly.
  • M2: harvest SoTA models and safety constraints as a reconstructible set (governed by G.2).
  • M3: generate policy‑constrained candidate protocols; emitter trace and evidence pins are mandatory.
  • M4: return the shortlisted protocols as a set, which may have one member. Choosing one from a shortlist of several requires an explicit decision policy.
  • M5/M6: publish and wire refresh (decay events, policy changes, and evidence updates retrigger along the P2W path).