CAD.Reference:3.1 - How information changes a command margin
CAD.5 constructs compatible state histories from the measurements available before the action. Past inputs must be the inputs applied to the plant; a planned input or a measured value treated as current can produce a different information set. A run-wide bound V_\eta must cover startup and every allowed delivery mode, not only a favorable observation window.
When the interface is
u=K(\hat x-Pz)+Qz+Rv,
CAD.5:4.7 derives the estimate-based version of CAD.2’s tracking equation:
e^+=Fe+Hz+Gv+w-BK\eta.
CAD.3 therefore receives the effective forcing W\oplus(-BK)V_\eta. For every admitted nominal state and command, its state and input tests become
\lbrace Pz\rbrace\oplus E\subseteq X,\qquad \lbrace Qz+Rv\rbrace\oplus KE\oplus(-K)V_\eta\subseteq U.
The separate set sums are sufficient enclosures, not assertions that tracking and estimation errors are independent. A tighter joint representation may recover a useful design that these separate margins reject. A failure of a sufficient enclosure is consequently different from CAD.5’s indistinguishability proof that no action can meet the demand.
This is a two-way design connection. A tighter required command domain can require fresher observations. A sensor or estimator change can enlarge V_\eta, shrink the usable command domain and invalidate a nominal performance claim. CAD.4 includes the cost of obtaining and updating that information. If a larger planner delays the estimator or communication, the old age bound is no longer a premise of the same realization. Reuse an unaffected result, but return the changed timing to CAD.5 and the resulting error to CAD.3.