CAD.4:4.3 - Include execution in the design equations

Use MMP.22 to turn the mathematical operation into a workable computation. Identify the data needed when the operation starts, the work that can be prepared ahead, the result required at its deadline, and what must happen if it is unavailable.

For isolated periodic tasks that each must finish before their next release, compare certified upper bounds on their response times with their periods:

C_{\mathrm{fast}}\leq T_{\mathrm{fast}},\qquad C_{\mathrm{plan}}\leq T_{\mathrm{plan}},

where each C includes the elapsed time from release of a task to the required delivery. Passing these tests certifies timing for that arrangement. A 6 ms upper estimate for a 5 ms deadline leaves timing open if the estimate is loose. An admissible late job defeats the deadline guarantee. On a shared processor, derive response bounds with blocking, interference and communication included. If delivery may extend past the next release, compare each result with its own deadline and the sustained workload with available capacity. For example, two independent 4 ms pipeline stages can deliver one result every 5 ms with a latency of 8 ms. This arrangement needs a consumer that permits that latency and supports the intervening commands.

If planning finishes one period after its observation, model that delay and the command that controls the intervening period. Preparing a future segment can make the delay harmless for a predetermined reference but not automatically for a newly observed obstacle. A faster processor can make another arrangement feasible when computation limited timely delivery and the new arrangement satisfies the other control and execution conditions.

For a design, account for unit conversions, numerical tolerances, update order, saturation and reset behavior that can affect the required duty. For a realized controller, establish how it handles those effects and which lower law it executes. Use applicable evidence already available. Test an unresolved effect or perform a new test when the assignment requires it. Include the optimizer’s constraint tolerance in the margin analysis if it can consume physical clearance.

If an online solver returns only a partial iterate, separate the time spent solving from the test that permits applying its output. A qualified acceptance rule may allow a feasible inexact result and otherwise keep an admissible prior command or plan. Include the cost of that test and the conditions for progress; a timeout says nothing about admissibility, and feasibility alone does not establish progress. The command-governor alternative in :11 is one developed construction, not a fallback rule for every optimizer.