C.2.2:4.4.A - Worked micro-example: scope revision and evidence reuse

A materials-lab claim says:

c_lab: “Adhesive X on Al6061 retains at least 85% of its initial tensile strength throughout exposure at 120–150 °C for up to two hours.”

The claim covers Al6061, actual adhesive temperatures from 120 to 150 °C and exposures of up to two hours. Call this scope G_lab. The supporting tests used rig Calib-v3. The lab accepts results from this rig for one year after testing. A plant engineer can restrict the operating conditions covered by the claim and then judge whether the lab tests support the restricted claim at Plant B.

  1. State the plant claim and its scope. At Plant B, assume calibration establishes |T_actual − T_reported| ≤ 2 °C throughout the intended operation (C.16). Restrict the claim to Plant B operating on Al6061 for up to two hours with readings in [122,148]°C. Every such exposure satisfies the original temperature condition under the stated bound. A reported 149 °C could correspond to an actual 151 °C, so this plant rule excludes that reading. A.2.6 governs this restriction.
  2. Judge reuse of the lab evidence. Identify the tests run on Calib-v3, establish whether their results are still current for the intended use, and check whether the material, loading and measurement conditions support the claim for the plant exposures. The temperature bound establishes which exposures the rule covers. It supplies no tensile-strength measurement. A declared fit CL=2 records the relation’s fit, not a probability decrement. State the actual reuse limitation. Calculate a numerical R_eff only if a receiving model establishes the R quantity and this loss; otherwise keep the separate support and qualified plant conclusion. This judgement does not perform the scope edit.

If lab and plant use distinct local meanings for a material term, F.9 separately tests a Bridge between their exact F.17 cells. Its semantic loss is not the calibration correction or the evidence-reuse result. A further safety narrowing of that reported-temperature interval to [125,145]°C is another explicit A.2.6 ΔG− decision.

The example therefore preserves one simple rule: name each changed value and relation once, change G only through the scope rule, and reduce R only through the loss rule that actually applies.