C.16:5.3 - Separate method, description, model, calibration, and work
M‑METH‑1. MeasurementMethod is one U.Method. Its U.MethodDescription may state generic participants, parameters, effects, and measurement conditions; it contains no actual-participant slots and does not claim that measurement occurred.
M‑MODEL‑1. MeasurementModel relates input values and relevant influences to the values attributed to the measurand. In quantity measurement, these are input, influence and output quantities. Identify the model version, assumptions, corrections and domain of validity. Recover what its formula, software function or other expression represents. Use C.16.MR to construct that relation from the indication-producing procedure when it is missing or unsuitable; :5.3.1 connects the construction to interpretation and its next use.
M‑CAL‑1. Name the calibration basis required for the use: reference standard or comparison basis, dated calibration work and result when required, calibration coefficients or corrections, applicable interval, and uncertainty contribution. A calibration certificate or ledger row cites these facts; it does not establish them by being stored.
M‑WORK‑1. A claim identifying MeasurementWork as one dated U.Work uses A.13 and A.15.1 at the claimed scale. Establish the actual performance, enacted Method, temporal extent and applicable containing-system relation. For a particular performer, establish its contribution to that action. Apply F.6 when attribution to its assignment matters. Identify the measurand through its direct subject relation or an A.6.1 operation-application binding. Use actual resource and participant bindings where the claim needs them. A reliable earlier result may already settle a question about the measured value. An order for another measurement, or for a specified party’s own measurement, requires grounds for that performance.
C.16:5.3.1 - Construct the measurement relation
- Start with what is being measured and why. Specify the subject, Characteristic, conditions and required range of interpretation under §§5.1-5.2. Separate what is already known from values the proposed measurement must resolve.
- Follow how the indication is produced. Describe the procedure connecting the subject to the indication. Recover the measurement principle, applicable calibration relation, or combination of both that connects the quantities. Include intermediate conversions when they change the answer. Physical laws, assessment models and instrument-specific relations come from the relevant subject knowledge; B.5:4.2 helps recover their construction.
- Include influential conditions. Consider how the apparatus interacts with the subject, what it samples or averages, and its resolution and operating range. Include an influence when its omission could change the interpretation needed for this use. Explain a correction through the relation that gives its direction and magnitude. Retain an unknown influential quantity as unknown, using available bounds or distributions when justified.
- Determine what the relation resolves. With actual or proposed indications, derive the compatible sought values and their uncertainty under §5.4. If different sought values can produce the same indication, identify that ambiguity. Work a small case or limiting case to expose an omitted influence, inconsistent units or a failed inversion. C.16.IR constructs the joint cases and distinguishes feasible alternatives from bounds that may include unattainable values.
- Choose the useful return. Supply the interpreted value, interval or conditional result when it answers the question. Otherwise identify which change could resolve the remaining ambiguity: refine the relation, change the measurement arrangement, obtain an applicable calibration or narrow the conclusion. Choose further observation by the distinction it can resolve and the work it demands, using C.11.DUA when that choice needs deliberation. C.16.RM compares changes to models, arrangements and calculation, then carries the selected repair through the interpretation while retaining the wanted quantity.
When an observed discrepancy matters, compare its plausible sources in the subject account, measurement relation and actual arrangement. Change the contribution that can alter the answer; sometimes removing an unwanted influence from the arrangement is more useful than modeling it in greater detail. A model-development result states the relation and what it would establish. A claim about a performed measurement also identifies the work and obtained result under §§5.3-5.5.
Instrument resolution describes how small a change in the measured quantity can produce a perceptible change in indication. Extra display digits alone establish neither that capability nor a smaller uncertainty in the result. When comparing two measurement models, hold the question, subject and conditions fixed or establish how the observations bear on the same quantity. Apply B.5.MR:4.2 if the claim is that the second model strictly refines the first. A change of instrument may supply new evidence for that comparison.